Absolute Maximum Ratings and Thermal Characteristics (TA=25°C unless otherwise specified)
PARAMETER | SYMBOL | LIMIT | UNITS | |
---|---|---|---|---|
Drain-Source Voltage | VDS | 80 | V | |
Gate-Source Voltage | VGS | ±20 | V | |
Continuous Drain Current | TC=25°C TC=100°C |
ID | 307 217 |
A |
Pulsed Drain Current | TC=25°C | IDM | 1226 | A |
Power Dissipation | TC=25°C TC=100°C |
PD | 333 167 |
W |
Operating Junction and Storage Temperature Range | TJ, TSTG | -55~175 | °C | |
Typical Thermal Resistance - Junction to Ambient |
RθJA | 40 | °C/W |
Electrical Characteristics (TA=25°C unless otherwise specified)
PARAMETER | SYMBOL | TEST CONDITION | MIN. | TYP. | MAX. | UNITS |
---|---|---|---|---|---|---|
Static | ||||||
Drain-Source Breakdown Voltage | BVDSS | VGS=0 V, ID=250 μA | 80 | - | - | V |
Gate Threshold Voltage | VGS(th> | VDS=VGS, ID=400 μA | 1.8 | 2.8 | 3.8 | V |
Drain-Source On-State Resistance | RDS(on) | VGS=10 V, ID=50 A VGS=7 V, ID=25 A |
- - |
1.6 2 |
2 3.3 |
mΩ |
Zero Gate Voltae Drain Current | IDSS | VDS=80 V, VGS=0 V | - | - | 1 | μA |
Gate-Source Leakage Current | IGSS | VGS=±20 V, VDS=0 V | - | - | ±100 | uA |
Dynamic | ||||||
Total Gate Charge Gate-Source Charge Gate-Drain Charge |
Qg Qgs Qgd |
VDS=40 V, ID=100 A, VGS=10 V |
- - - |
70 22.2 15.1 |
91 - - |
nC |
Input Capacitance Output Capacitance Reverse Transfer Capacitance |
Ciss Coss Crss |
VDS=40 V, VGS=0 V, f=250 kHZ |
- - - |
4577 2076 52.3 |
5950 2700 - |
pF |
Turn-On Delay Time Turn-On Rise Time Turn-Off Delay Time Turn-Off Fall Time |
td(on) tr td(off) tf |
VDD=40 V, ID=100 A, VGS=10 V, RG=1.6 Ω |
- - - - |
19 9 31.7 12 |
- - - - |
ns |
Gate Resistance | Rg | f=1.0 MHz | - | 0.6 | 1.2 | Ω |
Drain-Source Diode | ||||||
Diode Forward Voltage | VSD | IS=50 A, VGS=0 V | - | 0.9 | 1.2 | V |